Get Latest Price
Payment Type:L/C,T/T,D/P,Paypal,Money Gram,Western Union
Incoterm:FOB,CFR,CIF,FCA,CIP
Min. Order:200 Bag/Bags
Transportation:Ocean,Land,Air
Product Attributes

Model No.YL-QDF-1

BrandYL

Packaging & Delivery
Selling Units : Bag/Bags
Package Type : 200pieces/box
Product Description

Built-in break access jacks 10Pair Magazine Quick-Connect Distribution Frame QDF for protecting testing or breaking the circuits

 

Quick Detail:

 

1, Material: PBT or ABS(UL94V-0)

2, Contact: Phosphor Bronze

3, Silver Plating

4, Gas-tight contacts ensure a reliable and long lasting connection

5, Quick and reliable installations.

6, Vertical mounting pitch for space saving

7. Reliability of new wiring or rewiring

8. Use with ADC KRONE Back Mount Frame; Available for use with ADC KRONE profile rod mount brackets

 

Description:

 


It is a 10-pair magazine designed for applications in which there is or will be a need for protecting, testing or breaking the circuits. This includes distribution frames and on customer premises, as well as in outside plant installations.
It`s design provides built-in break access jacks which can be separated for testing in both directions on protected as well as unprotected circuits, for monitoring circuit performance or for circuit disconnection. The break access jacks also accept individual protector modules. The [make-before-break" design of the break access jacks enables testing and patching without any loss of signal; a substitute circuit is established through the tip of the plug before it breaks the original circuit.
The IDC contacts are housed in a thermoplastic termination block incorporating an integrated earthing strip which automatically connects to the metal mounting bracket when the magazine is installed.
A wide range of protection options is available, as is a broad selection of accessories, such as patch-cords, designation covers and wings, circuit markers and line-opening and line-grounding plugs.

 

The 4-wire retractable test/patch cord consists of a plastic plug assembly containing a moulded printed circuit board which can be extended from or retracted into the housing assembly. This unique design enables access for testing or monitoring circuits on the QDF-E termination magazine both with or without
installed protectors.

 

The punch down tool for the tyco IDC module ,we recommend you the YL-7030,with long head or short head for option.

 

Housing Material :polyester UL 94 V0 rated 
Split Cylinder Contact Material:High strength phosphor bronze with anti-corrosion coating.
Earthing Strip :High corrosion resistance brass with anti-corrosion coating.
Conductor Sizes Solid wire: 0.4 mm to 0.9 mm (26 to 19 AWG)
Stranded wire: 0.4 mm to 0.64 mm (26 to 22 AWG)
Note: If two wires are terminated on a contact, they must be the same size.
Wire Sizes Range accomodated (including insulation): 0.69 mm to 1.50 mm

 

Electrical Characteristics
Insulation resistance > 1000 GΩ at 500 Vdc
Dielectric withstand 2000 Vac for 5 mins
Current capacity 20 A total, 10 each line side to earth with no magazine distortion
Cross talk (average) -100 dB @ 20 kHz ,-70 dB @ 2.048 Mbps
Contact resistance (including the two split cylinders,contact between them, and wire contacts):7 mΩ maximum
Maximum change in resistance,∆R (after environmental testing): 2.5 mΩ per contact interface
Durability
Minimum 200 insertion and withdrawal cycles.

 

C5C-AC-ITS 9-1200738-0 Tyco C5C Termination Magazine Installation tool short version.

C5C-AC-ITL 6-1200740-4 Tyco C5C Termination Magazine Installation tool long version.

C5C-AC-ITIS 0-1731115-1 Tyco C5C Termination Magazine Installation tool short, Impact version

C5C-AC-ITIL 0-1731115-2 Tyco C5C Termination Magazine Installation tool long, Impact version

 Built In Break Access Jacks 10 Pair Magazine Quick Connect System Distribution Frame 3Built In Break Access Jacks 10 Pair Magazine Quick Connect System Distribution Frame 2Built In Break Access Jacks 10 Pair Magazine Quick Connect System Distribution Frame 1

Home> Products> Telecommunication Products> Connection Modules> Built - In Break Access Jacks 10 Pair Magazine Quick Connect System
Contact Us
Subscribe
Social Media

Copyright © 2024 NINGBO YULIANG TELECOM MUNICATIONS EQUIPMENT CO.,LTD. All rights reserved. Privacy Policy

Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send